Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 29.878
1.
Sci Rep ; 14(1): 10564, 2024 05 08.
Article En | MEDLINE | ID: mdl-38719859

Human instructors fluidly communicate with hand gestures, head and body movements, and facial expressions, but robots rarely leverage these complementary cues. A minimally supervised social robot with such skills could help people exercise and learn new activities. Thus, we investigated how nonverbal feedback from a humanoid robot affects human behavior. Inspired by the education literature, we evaluated formative feedback (real-time corrections) and summative feedback (post-task scores) for three distinct tasks: positioning in the room, mimicking the robot's arm pose, and contacting the robot's hands. Twenty-eight adults completed seventy-five 30-s-long trials with no explicit instructions or experimenter help. Motion-capture data analysis shows that both formative and summative feedback from the robot significantly aided user performance. Additionally, formative feedback improved task understanding. These results show the power of nonverbal cues based on human movement and the utility of viewing feedback through formative and summative lenses.


Robotics , Humans , Robotics/methods , Male , Female , Adult , Formative Feedback , Young Adult , Feedback
2.
Sci Rep ; 14(1): 10581, 2024 05 08.
Article En | MEDLINE | ID: mdl-38719925

This research is dedicated to exploring the dynamics of milling chatter stability in orthopedic surgery robots, focusing on the impact of position modal parameters on chatter stability. Initially, we develop a dynamic milling force model for the robotic milling process that integrates both modal coupling and regenerative effects. We then employ the zero-order frequency domain method to derive a chatter stability domain model, visually represented through stability lobe diagrams (SLDs). Through conducting hammer test experiments, we ascertain the robot's modal parameters at varying positions, enabling the precise generation of SLDs. This study also includes experimental validation of the chatter SLD analysis method, laying the groundwork for further examination of chatter stability across different positional modal parameters. Finally, our analysis of the variations in modal parameters on the stability of robot milling chatter yields a theoretical framework for optimizing cutting parameters and developing control strategies within the context of orthopedic surgery robots.


Orthopedic Procedures , Orthopedic Procedures/methods , Orthopedic Procedures/instrumentation , Robotic Surgical Procedures/methods , Robotics/methods , Models, Theoretical , Humans , Equipment Design
3.
BMC Neurol ; 24(1): 144, 2024 May 09.
Article En | MEDLINE | ID: mdl-38724916

BACKGROUND: Restoring shoulder function is critical for upper-extremity rehabilitation following a stroke. The complex musculoskeletal anatomy of the shoulder presents a challenge for safely assisting elevation movements through robotic interventions. The level of shoulder elevation assistance in rehabilitation is often based on clinical judgment. There is no standardized method for deriving an optimal level of assistance, underscoring the importance of addressing abnormal movements during shoulder elevation, such as abnormal synergies and compensatory actions. This study aimed to investigate the effectiveness and safety of a newly developed shoulder elevation exoskeleton robot by applying a novel optimization technique derived from the muscle synergy index. METHODS: Twelve chronic stroke participants underwent an intervention consisting of 100 robot-assisted shoulder elevation exercises (10 × 10 times, approximately 40 min) for 10 days (4-5 times/week). The optimal robot assist rate was derived by detecting the change points using the co-contraction index, calculated from electromyogram (EMG) data obtained from the anterior deltoid and biceps brachii muscles during shoulder elevation at the initial evaluation. The primary outcomes were the Fugl-Meyer assessment-upper extremity (FMA-UE) shoulder/elbow/forearm score, kinematic outcomes (maximum angle of voluntary shoulder flexion and elbow flexion ratio during shoulder elevation), and shoulder pain outcomes (pain-free passive shoulder flexion range of motion [ROM] and visual analogue scale for pain severity during shoulder flexion). The effectiveness and safety of robotic therapy were examined using the Wilcoxon signed-rank sum test. RESULTS: All 12 patients completed the procedure without any adverse events. Two participants were excluded from the analysis because the EMG of the biceps brachii was not obtained. Ten participants (five men and five women; mean age: 57.0 [5.5] years; mean FMA-UE total score: 18.7 [10.5] points) showed significant improvement in the FMA-UE shoulder/elbow/forearm score, kinematic outcomes, and pain-free passive shoulder flexion ROM (P < 0.05). The shoulder pain outcomes remained unchanged or improved in all patients. CONCLUSIONS: The study presents a method for deriving the optimal robotic assist rate. Rehabilitation using a shoulder robot based on this derived optimal assist rate showed the possibility of safely improving the upper-extremity function in patients with severe stroke in the chronic phase.


Electromyography , Exoskeleton Device , Feasibility Studies , Muscle, Skeletal , Shoulder , Stroke Rehabilitation , Humans , Male , Female , Stroke Rehabilitation/methods , Middle Aged , Aged , Shoulder/physiopathology , Shoulder/physiology , Electromyography/methods , Muscle, Skeletal/physiopathology , Muscle, Skeletal/physiology , Range of Motion, Articular/physiology , Exercise Therapy/methods , Stroke/physiopathology , Robotics/methods , Biomechanical Phenomena/physiology , Adult
4.
J Pak Med Assoc ; 74(4 (Supple-4)): S79-S84, 2024 Apr.
Article En | MEDLINE | ID: mdl-38712413

Dental Robotics represent a groundbreaking technological frontier with the potential to disrupt traditional paradigms in oral healthcare. This abstract explores the transformative impact of robotic applications in dentistry, focussing on precision, reproducibility, and reliability. A comprehensive search was conducted on the PubMed database, Dental and Oral Science, and CINAHL to identify pertinent studies exploring the implications of robotics in dentistry. Studies incorporated in this analysis highlighted the significance of broadening the research scope beyond implantology. This review underscores the importance of integrating robotic dentistry into educational frameworks and advancing technological preparedness. As we navigate these challenges, the abstract underscores the pivotal role of robotic dentistry in shaping the future of oral healthcare. Robotic dentistry promises transformative advancements in oral healthcare with precision and reliability. Challenges like limited system availability and expertise highlight the need for increased dentist-engineer collaboration. Diversifying research, emphasizing non-invasive technologies, and integrating robotic dentistry into education are crucial for wider acceptance. Public awareness and regulatory clarity are pivotal for seamless integration, unlocking the vast potential of robotic technologies in the future of dental care.


Robotics , Humans , Dentistry , Robotic Surgical Procedures/methods
5.
Nat Commun ; 15(1): 4004, 2024 May 11.
Article En | MEDLINE | ID: mdl-38734697

The current thyroid ultrasound relies heavily on the experience and skills of the sonographer and the expertise of the radiologist, and the process is physically and cognitively exhausting. In this paper, we report a fully autonomous robotic ultrasound system, which is able to scan thyroid regions without human assistance and identify malignant nod- ules. In this system, human skeleton point recognition, reinforcement learning, and force feedback are used to deal with the difficulties in locating thyroid targets. The orientation of the ultrasound probe is adjusted dynamically via Bayesian optimization. Experimental results on human participants demonstrated that this system can perform high-quality ultrasound scans, close to manual scans obtained by clinicians. Additionally, it has the potential to detect thyroid nodules and provide data on nodule characteristics for American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) calculation.


Robotics , Thyroid Gland , Thyroid Nodule , Ultrasonography , Humans , Thyroid Gland/diagnostic imaging , Ultrasonography/methods , Ultrasonography/instrumentation , Robotics/methods , Robotics/instrumentation , Thyroid Nodule/diagnostic imaging , Thyroid Nodule/pathology , Bayes Theorem , Female , Adult , Male , Thyroid Neoplasms/diagnostic imaging
6.
J Neuroeng Rehabil ; 21(1): 77, 2024 May 14.
Article En | MEDLINE | ID: mdl-38745227

BACKGROUND: Over 80% of patients with stroke experience finger grasping dysfunction, affecting independence in activities of daily living and quality of life. In routine training, task-oriented training is usually used for functional hand training, which may improve finger grasping performance after stroke, while augmented therapy may lead to a better treatment outcome. As a new technology-supported training, the hand rehabilitation robot provides opportunities to improve the therapeutic effect by increasing the training intensity. However, most hand rehabilitation robots commonly applied in clinics are based on a passive training mode and lack the sensory feedback function of fingers, which is not conducive to patients completing more accurate grasping movements. A force feedback hand rehabilitation robot can compensate for these defects. However, its clinical efficacy in patients with stroke remains unknown. This study aimed to investigate the effectiveness and added value of a force feedback hand rehabilitation robot combined with task-oriented training in stroke patients with hemiplegia. METHODS: In this single-blinded randomised controlled trial, 44 stroke patients with hemiplegia were randomly divided into experimental (n = 22) and control (n = 22) groups. Both groups received 40 min/day of conventional upper limb rehabilitation training. The experimental group received 20 min/day of task-oriented training assisted by a force feedback rehabilitation robot, and the control group received 20 min/day of task-oriented training assisted by therapists. Training was provided for 4 weeks, 5 times/week. The Fugl-Meyer motor function assessment of the hand part (FMA-Hand), Action Research Arm Test (ARAT), grip strength, Modified Ashworth scale (MAS), range of motion (ROM), Brunnstrom recovery stages of the hand (BRS-H), and Barthel index (BI) were used to evaluate the effect of two groups before and after treatment. RESULTS: Intra-group comparison: In both groups, the FMA-Hand, ARAT, grip strength, AROM, BRS-H, and BI scores after 4 weeks of treatment were significantly higher than those before treatment (p < 0.05), whereas there was no significant difference in finger flexor MAS scores before and after treatment (p > 0.05). Inter-group comparison: After 4 weeks of treatment, the experimental group's FMA-Hand total score, ARAT, grip strength, and AROM were significantly better than those of the control group (p < 0.05). However, there were no statistically significant differences in the scores of each sub-item of the FMA-Hand after Bonferroni correction (p > 0.007). In addition, there were no statistically significant differences in MAS, BRS-H, and BI scores (p > 0.05). CONCLUSION: Hand performance improved in patients with stroke after 4 weeks of task-oriented training. The use of a force feedback hand rehabilitation robot to support task-oriented training showed additional value over conventional task-oriented training in stroke patients with hand dysfunction. CLINICAL TRIAL REGISTRATION INFORMATION: NCT05841108.


Hand Strength , Hemiplegia , Robotics , Stroke Rehabilitation , Humans , Stroke Rehabilitation/methods , Stroke Rehabilitation/instrumentation , Male , Female , Middle Aged , Robotics/instrumentation , Hand Strength/physiology , Hemiplegia/rehabilitation , Hemiplegia/physiopathology , Hemiplegia/etiology , Aged , Single-Blind Method , Stroke/complications , Stroke/physiopathology , Fingers/physiology , Fingers/physiopathology , Hand/physiopathology , Adult , Feedback, Sensory/physiology , Treatment Outcome , Recovery of Function
7.
J Neuroeng Rehabil ; 21(1): 76, 2024 May 14.
Article En | MEDLINE | ID: mdl-38745235

BACKGROUND: Gait disorder remains a major challenge for individuals with stroke, affecting their quality of life and increasing the risk of secondary complications. Robot-assisted gait training (RAGT) has emerged as a promising approach for improving gait independence in individuals with stroke. This study aimed to evaluate the effect of RAGT in individuals with subacute hemiparetic stroke using a one-leg assisted gait robot called Welwalk WW-1000. METHODS: An assessor-blinded, multicenter randomized controlled trial was conducted in the convalescent rehabilitation wards of eight hospitals in Japan. Participants with first-ever hemiparetic stroke who could not walk at pre-intervention assessment were randomized to either the Welwalk group, which underwent RAGT with conventional physical therapy, or the control group, which underwent conventional physical therapy alone. Both groups received 80 min of physical therapy per day, 7 days per week, while the Welwalk group received 40 min of RAGT per day, 6 days per week, as part of their physical therapy. The primary outcome was gait independence, as assessed using the Functional Independence Measure Walk Score. RESULTS: A total of 91 participants were enrolled, 85 of whom completed the intervention. As a result, 91 participants, as a full analysis set, and 85, as a per-protocol set, were analyzed. The primary outcome, the cumulative incidence of gait-independent events, was not significantly different between the groups. Subgroup analysis revealed that the interaction between the intervention group and stroke type did not yield significant differences in either the full analysis or per-protocol set. However, although not statistically significant, a discernible trend toward improvement with Welwalk was observed in cases of cerebral infarction for the full analysis and per-protocol sets (HR 4.167 [95%CI 0.914-18.995], p = 0.065, HR 4.443 [95%CI 0.973-20.279], p = 0.054, respectively). CONCLUSIONS: The combination of RAGT using Welwalk and conventional physical therapy was not significantly more effective than conventional physical therapy alone in promoting gait independence in individuals with subacute hemiparetic stroke, although a trend toward earlier gait independence was observed in individuals with cerebral infarction. TRIAL REGISTRATION: This study was registered with the Japan Registry of Clinical Trials ( https://jrct.niph.go.jp ; jRCT 042180078) on March 3, 2019.


Gait Disorders, Neurologic , Paresis , Robotics , Stroke Rehabilitation , Stroke , Humans , Male , Stroke Rehabilitation/methods , Stroke Rehabilitation/instrumentation , Female , Aged , Robotics/methods , Robotics/instrumentation , Middle Aged , Gait Disorders, Neurologic/rehabilitation , Gait Disorders, Neurologic/etiology , Paresis/rehabilitation , Paresis/etiology , Stroke/complications , Gait/physiology , Exercise Therapy/methods , Exercise Therapy/instrumentation , Single-Blind Method , Physical Therapy Modalities/instrumentation , Treatment Outcome
8.
PLoS One ; 19(5): e0291279, 2024.
Article En | MEDLINE | ID: mdl-38739557

Upper limb robotic (myoelectric) prostheses are technologically advanced, but challenging to use. In response, substantial research is being done to develop person-specific prosthesis controllers that can predict a user's intended movements. Most studies that test and compare new controllers rely on simple assessment measures such as task scores (e.g., number of objects moved across a barrier) or duration-based measures (e.g., overall task completion time). These assessment measures, however, fail to capture valuable details about: the quality of device arm movements; whether these movements match users' intentions; the timing of specific wrist and hand control functions; and users' opinions regarding overall device reliability and controller training requirements. In this work, we present a comprehensive and novel suite of myoelectric prosthesis control evaluation metrics that better facilitates analysis of device movement details-spanning measures of task performance, control characteristics, and user experience. As a case example of their use and research viability, we applied these metrics in real-time control experimentation. Here, eight participants without upper limb impairment compared device control offered by a deep learning-based controller (recurrent convolutional neural network-based classification with transfer learning, or RCNN-TL) to that of a commonly used controller (linear discriminant analysis, or LDA). The participants wore a simulated prosthesis and performed complex functional tasks across multiple limb positions. Analysis resulting from our suite of metrics identified 16 instances of a user-facing problem known as the "limb position effect". We determined that RCNN-TL performed the same as or significantly better than LDA in four such problem instances. We also confirmed that transfer learning can minimize user training burden. Overall, this study contributes a multifaceted new suite of control evaluation metrics, along with a guide to their application, for use in research and testing of myoelectric controllers today, and potentially for use in broader rehabilitation technologies of the future.


Artificial Limbs , Electromyography , Humans , Male , Female , Adult , Prosthesis Design , Upper Extremity/physiology , Robotics , Movement/physiology , Neural Networks, Computer , Young Adult , Deep Learning
9.
J Biosci ; 492024.
Article En | MEDLINE | ID: mdl-38726823

Can one design and automate a computational and experimental platform such that each platform iteratively guides and drives the other to achieve a pre-determined goal? Rapp and colleagues (2024) describe just this possibility in a paper that details a prototype of a self-driven laboratory that can navigate autonomously to yield an engineered enzyme with a desired attribute. This laboratory, rather, the automated protocol, is referred to by an acronym - SAMPLE. This refers to Self-driving Autonomous Machines for Protein Landscape Exploration. The paper describes a prototype involving the engineering of a glycoside hydrolase for enhanced thermostability. The 'brain', the computational component behind this automated system, was designed to learn protein sequence- function relationships from a curated dataset. These designer proteins were then evaluated by a fully automated robotic system that could synthesize and experimentally characterize the designed protein and provide feedback to the agent, i.e., the computational component, to fine-tune its understanding of the system. The SAMPLE agents were thus designed to continually refine their understanding of the protein landscape by actively acquiring information in the search process. As this intelligent agent learns protein sequence-function relationships from a curated, diverse dataset, this feedback is crucial to refine landscape exploration and the design of new proteins based on the updated hypothesis. In this prototype, four SAMPLE agents were tasked with this goal. The goal of each of these agents was to navigate the glycoside hydrolase landscape and identify enzymes with enhanced thermal tolerance. Differences in the search behavior of individual agents primarily arise from experimental measurement noise. However, despite differences in their search behavior, all four agents could converge on a thermostable glycoside hydrolase - a remarkable feat as it apparently did not need any human intervention.


Glycoside Hydrolases , Protein Engineering , Protein Engineering/methods , Glycoside Hydrolases/chemistry , Glycoside Hydrolases/genetics , Glycoside Hydrolases/metabolism , Robotics , Enzyme Stability
10.
Neurosurg Rev ; 47(1): 214, 2024 May 10.
Article En | MEDLINE | ID: mdl-38727832

The letter critically evaluates the role of robotic applications in cerebral aneurysm neurointerventions, synthesizing a diverse array of studies to elucidate both the potential benefits and inherent limitations of this emerging technology. The review highlights the advancements in precision, efficiency, and patient outcomes facilitated by robotic platforms, while also acknowledging challenges such as the steep learning curve and the need for further research to establish long-term efficacy and cost-effectiveness. By navigating through the complexities of robotic-assisted neurosurgery, the review provides valuable insights into the transformative potential of robotics in optimizing treatment paradigms and improving patient care.


Intracranial Aneurysm , Neurosurgical Procedures , Robotic Surgical Procedures , Intracranial Aneurysm/surgery , Humans , Robotic Surgical Procedures/methods , Neurosurgical Procedures/methods , Endovascular Procedures/methods , Robotics/methods
11.
Nat Commun ; 15(1): 3759, 2024 May 04.
Article En | MEDLINE | ID: mdl-38704384

Millimeter-scale soft continuum robots offer safety and adaptability in transluminal procedures due to their passive compliance, but this feature necessitates interactions with surrounding lumina, leading to potential medical risks and restricted mobility. Here, we introduce a millimeter-scale continuum robot, enabling apical extension while maintaining structural stability. Utilizing phase transition components, the robot executes cycles of tip-based elongation, steered accurately through programmable magnetic fields. Each motion cycle features a solid-like backbone for stability, and a liquid-like component for advancement, thereby enabling autonomous shaping without reliance on environmental interactions. Together with clinical imaging technologies, we demonstrate the capability of navigating through tortuous and fragile lumina to transport microsurgical tools. Once it reaches larger anatomical spaces such as stomach, it can morph into functional 3D structures that serve as surgical tools or sensing units, overcoming the constraints of initially narrow pathways. By leveraging this design paradigm, we anticipate enhanced safety, multi-functionality, and cooperative capabilities among millimeter-scale continuum robots, opening new avenues for transluminal robotic surgery.


Robotic Surgical Procedures , Robotic Surgical Procedures/instrumentation , Robotic Surgical Procedures/methods , Humans , Equipment Design , Robotics/instrumentation , Robotics/methods , Magnetic Fields , Microsurgery/instrumentation , Microsurgery/methods , Animals , Magnetics
12.
J R Soc Interface ; 21(214): 20230737, 2024 May.
Article En | MEDLINE | ID: mdl-38689546

Patterns of collective escape of a bird flock from a predator are fascinating, but difficult to study under natural conditions because neither prey nor predator is under experimental control. We resolved this problem by using an artificial predator (RobotFalcon) resembling a peregrine falcon in morphology and behaviour. We imitated hunts by chasing flocks of corvids, gulls, starlings and lapwings with the RobotFalcon, and compared their patterns of collective escape to those when chased by a conventional drone and, in case of starlings, hunted by wild peregrine falcons. Active pursuit of flocks, rather than only flying nearby by either the RobotFalcon or the drone, made flocks collectively escape more often. The RobotFalcon elicited patterns of collective escape in flocks of all species more often than the drone. Attack altitude did not affect the frequency of collective escape. Starlings escaped collectively equally often when chased by the RobotFalcon or a wild peregrine falcon. Flocks of all species reacted most often by collective turns, second most often by compacting and third by splitting into subflocks. This study demonstrates the potential of an artificial aerial predator for studying the collective escape behaviour of free-living birds, opening exciting avenues in the empirical study of prey-predator interactions.


Escape Reaction , Falconiformes , Robotics , Animals , Escape Reaction/physiology , Falconiformes/physiology , Predatory Behavior/physiology , Birds/physiology , Species Specificity
13.
Int J Mol Sci ; 25(9)2024 May 02.
Article En | MEDLINE | ID: mdl-38732200

We are living in an era of advanced nanoscience and nanotechnology. Numerous nanomaterials, culminating in nanorobots, have demonstrated ingenious applications in biomedicine, including breast cancer (BC) nano-theranostics. To solve the complicated problem of BC heterogeneity, non-targeted drug distribution, invasive diagnostics or surgery, resistance to classic onco-therapies and real-time monitoring of tumors, nanorobots are designed to perform multiple tasks at a small scale, even at the organelles or molecular level. Over the last few years, most nanorobots have been bioengineered as biomimetic and biocompatible nano(bio)structures, resembling different organisms and cells, such as urchin, spider, octopus, fish, spermatozoon, flagellar bacterium or helicoidal cyanobacterium. In this review, readers will be able to deepen their knowledge of the structure, behavior and role of several types of nanorobots, among other nanomaterials, in BC theranostics. We summarized here the characteristics of many functionalized nanodevices designed to counteract the main neoplastic hallmark features of BC, from sustaining proliferation and evading anti-growth signaling and resisting programmed cell death to inducing angiogenesis, activating invasion and metastasis, preventing genomic instability, avoiding immune destruction and deregulating autophagy. Most of these nanorobots function as targeted and self-propelled smart nano-carriers or nano-drug delivery systems (nano-DDSs), enhancing the efficiency and safety of chemo-, radio- or photodynamic therapy, or the current imagistic techniques used in BC diagnosis. Most of these nanorobots have been tested in vitro, using various BC cell lines, as well as in vivo, mainly based on mice models. We are still waiting for nanorobots that are low-cost, as well as for a wider transition of these favorable effects from laboratory to clinical practice.


Breast Neoplasms , Nanotechnology , Humans , Breast Neoplasms/pathology , Breast Neoplasms/therapy , Breast Neoplasms/diagnosis , Female , Nanotechnology/methods , Animals , Nanostructures/chemistry , Nanostructures/therapeutic use , Robotics/methods , Theranostic Nanomedicine/methods , Drug Delivery Systems/methods , Antineoplastic Agents/therapeutic use , Antineoplastic Agents/pharmacology
14.
Sensors (Basel) ; 24(9)2024 Apr 23.
Article En | MEDLINE | ID: mdl-38732782

In robot-assisted microsurgery (RAMS), surgeons often face the challenge of operating with minimal feedback, particularly lacking in haptic feedback. However, most traditional desktop haptic devices have restricted operational areas and limited dexterity. This report describes a novel, lightweight, and low-budget wearable haptic controller for teleoperated microsurgical robotic systems. We designed a wearable haptic interface entirely made using off-the-shelf material-PolyJet Photopolymer, fabricated using liquid and solid hybrid 3D co-printing technology. This interface was designed to resemble human soft tissues and can be wrapped around the fingertips, offering direct contact feedback to the operator. We also demonstrated that the device can be easily integrated with our motion tracking system for remote microsurgery. Two motion tracking methods, marker-based and marker-less, were compared in trajectory-tracking experiments at different depths to find the most effective motion tracking method for our RAMS system. The results indicate that within the 4 to 8 cm tracking range, the marker-based method achieved exceptional detection rates. Furthermore, the performance of three fusion algorithms was compared to establish the unscented Kalman filter as the most accurate and reliable. The effectiveness of the wearable haptic controller was evaluated through user studies focusing on the usefulness of haptic feedback. The results revealed that haptic feedback significantly enhances depth perception for operators during teleoperated RAMS.


Microsurgery , Robotic Surgical Procedures , Wearable Electronic Devices , Humans , Robotic Surgical Procedures/instrumentation , Robotic Surgical Procedures/methods , Microsurgery/instrumentation , Algorithms , Robotics/instrumentation , Equipment Design , Printing, Three-Dimensional
15.
Sensors (Basel) ; 24(9)2024 Apr 28.
Article En | MEDLINE | ID: mdl-38732923

The transition to Industry 4.0 and 5.0 underscores the need for integrating humans into manufacturing processes, shifting the focus towards customization and personalization rather than traditional mass production. However, human performance during task execution may vary. To ensure high human-robot teaming (HRT) performance, it is crucial to predict performance without negatively affecting task execution. Therefore, to predict performance indirectly, significant factors affecting human performance, such as engagement and task load (i.e., amount of cognitive, physical, and/or sensory resources required to perform a particular task), must be considered. Hence, we propose a framework to predict and maximize the HRT performance. For the prediction of task performance during the development phase, our methodology employs features extracted from physiological data as inputs. The labels for these predictions-categorized as accurate performance or inaccurate performance due to high/low task load-are meticulously crafted using a combination of the NASA TLX questionnaire, records of human performance in quality control tasks, and the application of Q-Learning to derive task-specific weights for the task load indices. This structured approach enables the deployment of our model to exclusively rely on physiological data for predicting performance, thereby achieving an accuracy rate of 95.45% in forecasting HRT performance. To maintain optimized HRT performance, this study further introduces a method of dynamically adjusting the robot's speed in the case of low performance. This strategic adjustment is designed to effectively balance the task load, thereby enhancing the efficiency of human-robot collaboration.


Robotics , Task Performance and Analysis , Humans , Robotics/methods , Female , Male , Data Analysis , Man-Machine Systems , Adult , Workload
16.
Sensors (Basel) ; 24(9)2024 May 03.
Article En | MEDLINE | ID: mdl-38733030

This article presents a study on the neurobiological control of voluntary movements for anthropomorphic robotic systems. A corticospinal neural network model has been developed to control joint trajectories in multi-fingered robotic hands. The proposed neural network simulates cortical and spinal areas, as well as the connectivity between them, during the execution of voluntary movements similar to those performed by humans or monkeys. Furthermore, this neural connection allows for the interpretation of functional roles in the motor areas of the brain. The proposed neural control system is tested on the fingers of a robotic hand, which is driven by agonist-antagonist tendons and actuators designed to accurately emulate complex muscular functionality. The experimental results show that the corticospinal controller produces key properties of biological movement control, such as bell-shaped asymmetric velocity profiles and the ability to compensate for disturbances. Movements are dynamically compensated for through sensory feedback. Based on the experimental results, it is concluded that the proposed biologically inspired adaptive neural control system is robust, reliable, and adaptable to robotic platforms with diverse biomechanics and degrees of freedom. The corticospinal network successfully integrates biological concepts with engineering control theory for the generation of functional movement. This research significantly contributes to improving our understanding of neuromotor control in both animals and humans, thus paving the way towards a new frontier in the field of neurobiological control of anthropomorphic robotic systems.


Hand , Neural Networks, Computer , Robotics , Tendons , Humans , Robotics/methods , Hand/physiology , Tendons/physiology , Movement/physiology , Nerve Net/physiology , Biomechanical Phenomena/physiology , Pyramidal Tracts/physiology , Animals
17.
Article En | MEDLINE | ID: mdl-38696295

This review aims to provide a systematic analysis of the literature focused on the use of intelligent control systems in robotics for physical rehabilitation, identifying trends in recent research and comparing the effectiveness of intelligence used in control, with the aim of determining important factors in robot-assisted rehabilitation and how intelligent controller design can improve them. Seven electronic research databases were searched for articles published in the years 2015 - 2022 with articles selected based on relevance to the subject area of intelligent control systems in rehabilitation robotics. It was found that the most common use of intelligent algorithms for control is improving traditional control strategies with optimization and learning techniques. Intelligent algorithms are also commonly used in sensor output mapping, model construction, and for various data learning purposes. Experimental results show that intelligent controllers consistently outperform non-intelligent controllers in terms of transparency, tracking accuracy, and adaptability. Active participation of the patients and lowered interaction forces are consistently mentioned as important factors in improving the rehabilitation outcome as well as the patient experience. However, there are limited examples of studies presenting experimental results with impaired participants suffering limited range of motion, so the effectiveness of therapy provided by these systems is often difficult to quantify. A lack of universal evaluation criteria also makes it difficult to compare control systems outside of articles which use their own comparison criteria.


Algorithms , Artificial Intelligence , Robotics , Humans , Rehabilitation/methods , Rehabilitation/instrumentation , Treatment Outcome
18.
Bioinspir Biomim ; 19(4)2024 May 07.
Article En | MEDLINE | ID: mdl-38631362

Soft-bodied animals, such as worms and snakes, use many muscles in different ways to traverse unstructured environments and inspire tools for accessing confined spaces. They demonstrate versatility of locomotion which is essential for adaptation to changing terrain conditions. However, replicating such versatility in untethered soft-bodied robots with multimodal locomotion capabilities have been challenging due to complex fabrication processes and limitations of soft body structures to accommodate hardware such as actuators, batteries and circuit boards. Here, we present MetaCrawler, a 3D printed metamaterial soft robot designed for multimodal and omnidirectional locomotion. Our design approach facilitated an easy fabrication process through a discrete assembly of a modular nodal honeycomb lattice with soft and hard components. A crucial benefit of the nodal honeycomb architecture is the ability of its hard components, nodes, to accommodate a distributed actuation system, comprising servomotors, control circuits, and batteries. Enabled by this distributed actuation, MetaCrawler achieves five locomotion modes: peristalsis, sidewinding, sideways translation, turn-in-place, and anguilliform. Demonstrations showcase MetaCrawler's adaptability in confined channel navigation, vertical traversing, and maze exploration. This soft robotic system holds the potential to offer easy-to-fabricate and accessible solutions for multimodal locomotion in applications such as search and rescue, pipeline inspection, and space missions.


Equipment Design , Locomotion , Robotics , Robotics/instrumentation , Robotics/methods , Locomotion/physiology , Animals , Biomimetic Materials , Printing, Three-Dimensional , Biomimetics/methods , Biomimetics/instrumentation
19.
Bioinspir Biomim ; 19(4)2024 May 07.
Article En | MEDLINE | ID: mdl-38648793

The human toe, characterized by its rigid-flexible structure comprising hard bones and flexible joints, facilitates adaptive and stable movement across varied terrains. In this paper, we utilized a motion capture system to study the adaptive adjustments of toe joints when encountering obstacles. Inspired by the mechanics of toe joints, we proposed a novel design method for a rigid-flexible coupled wheel. The wheel comprises multiple elements: a rigid skeleton, supporting toes, connecting shafts, torsion springs, soft tendons, and damping pads. The torsion springs connect the rigid frame to the supporting toes, enabling them to adapt to uneven terrains and pipes with different diameters. The design was validated through kinematic and dynamic modeling, rigid-flexible coupled dynamics simulation, and stress analysis. Different stiffness coefficients of torsion springs were compared for optimal wheel design. Then, the wheel was applied to a sewer robot, and its performance was evaluated and compared with a pneumatic rubber tire in various experiments, including movement on flat surfaces, overcoming small obstacles, adaptability tests in different terrains, and active driving force tests in dry and wet pipelines. The results prove that the designed wheel showed better stability and anti-slip properties than conventional tires, making it suitable for diverse applications such as pipeline robots, desert vehicles, and lunar rovers.


Equipment Design , Robotics , Robotics/instrumentation , Humans , Biomechanical Phenomena , Toes/physiology , Biomimetics/methods , Biomimetics/instrumentation , Models, Biological , Toe Joint/physiology , Computer Simulation , Movement/physiology
20.
J Robot Surg ; 18(1): 176, 2024 Apr 17.
Article En | MEDLINE | ID: mdl-38630145

The objective is to preliminary evaluated postoperative leukocyte counts as a surrogate for the surgical stress response in NSCLC patients who underwent RATS or VATS for further prospective analyses with proper assessment of surgical stress response and tissue trauma. We retrospectively analyzed patients with stageI-IIIA NSCLC who underwent RATS or VATS at a hospital between 8 May 2020 and 31 December 2021. Analysis of leukocytes (including neutrophils and lymphocytes) and albumin on postoperative days (PODs) 1 and 3 in patients with NSCLC treated with RATS or VATS after propensity score matching (PSM). In total, 1824 patients (565 RATS and 1259 VATS) were investigated. The two MIS groups differed significantly with regard to operative time (p < 0.001), chronic lung disease (p < 0.001), the type of pulmonary resection (p < 0.001), the excision site of lobectomy (p = 0.004), and histology of the tumor (p = 0.028). After PSM, leukocyte and neutrophil levels in the RATS group were lower than those in the VATS group on PODs 1 and 3, with those on POD 3 (p < 0.001) being particularly notable. While lymphocyte levels in the RATS group were significantly lower than those in the VATS group only at POD 1 (p = 0.016). There was no difference in albumin levels between the RATS and VATS groups on PODs 1 and 3. The surgical stress response and tissue trauma was less severe in NSCLC patients who underwent RATS than in those who underwent VATS, especially reflected in the neutrophils of leukocytes.


Carcinoma, Non-Small-Cell Lung , Lung Neoplasms , Robotic Surgical Procedures , Robotics , Humans , Thoracic Surgery, Video-Assisted , Retrospective Studies , Robotic Surgical Procedures/methods , Leukocyte Count , Carcinoma, Non-Small-Cell Lung/surgery , Albumins , Lung Neoplasms/surgery
...